Flare Ultrasonic Flow Meter
TSB supplies Flare Ultrasonic Flow Meters in Jordan for reliable measurement of flare gas flow in refineries, petrochemical plants, natural gas processing facilities and LNG applications. Ultrasonic technology provides accurate measurement across extremely wide flow ranges, including very low flare gas velocities during normal operation and rapid high-velocity flows during shutdown or emergency conditions.
The measuring principle uses ultrasonic transit-time measurement to determine gas velocity and flow without restricting the flare line. Advanced measurement and diagnostic capabilities also support monitoring of changing gas composition, gas losses and overall flare system performance.
Product Overview
Flare Ultrasonic Flow Meters combine:
- Gas velocity measurement from approximately 0.03 to 120 m/s
- Mass and volumetric flow measurement
- Actual and standard volume measurement
- Gas volume and mass totalization
- Molecular weight measurement
- Sound velocity measurement
- Direct mass flow calculation
- Pipe sizes from approximately 4 to 86 in
- 1-path and 2-path measurement configurations
- Process temperatures from -196°C to +280°C
- Operating pressures up to approximately 20 bar(g)
- Integrated diagnostics and predictive maintenance functions
Typical Technical Range
| Specification | Typical Range |
|---|---|
| Measuring Principle | Ultrasonic transit-time difference |
| Measuring Medium | Flare and process gases |
| Gas Velocity | 0.03 – 120 m/s |
| Volumetric Flow Accuracy | Approximately 1 – 5% depending on configuration |
| Calibrated Volumetric Flow Accuracy | Approximately 0.5 – 1.5% |
| Medium Temperature | -196°C to +280°C |
| Operating Pressure | Up to approximately 20 bar(g) |
| Pipe Size – 1 Path | 4 – 86 in |
| Pipe Size – 2 Path | 12 – 86 in |
| Measured Variables | Mass flow, actual/standard volume flow, molecular weight, gas velocity and sound velocity |
| Analog Output | 4–20 mA |
| Digital Communication | HART, Modbus and FOUNDATION Fieldbus |
| Hazardous Areas | ATEX, IECEx and other configurations available |
Specifications and available options may vary. Contact TSB for full details and configuration support.
Key Features
- Extremely wide measuring range for both low and high flare gas velocities
- Reliable measurement during rapidly changing flare conditions
- Suitable for changing gas compositions
- Direct mass flow calculation without an additional gas analyzer
- Simultaneous measurement of gas velocity, volume, mass flow and molecular weight
- Full-bore measurement without significant flow restriction
- 1-path and 2-path measurement configurations
- High-temperature and cryogenic measurement capability
- Integrated self-monitoring and self-testing
- Advanced diagnostics for predictive maintenance
- Verification functions for measurement performance monitoring
- Multiple analog and digital communication options
- Hazardous-area configurations for refinery and petrochemical applications
- Retrofit and upgrade configurations available for existing flare metering systems
Applications
- Refinery flare systems
- Petrochemical plants
- Chemical plants
- Natural gas processing
- Associated petroleum gas
- Flare gas loss monitoring
- Flare gas leak detection
- LNG boil-off gas
- Steam injection monitoring
- Flare combustion optimization
- Environmental reporting
- Process optimization
- Plant shutdown and emergency flare monitoring
- Oil and gas production facilities
Why Choose Flare Ultrasonic Flow Measurement?
Flare gas measurement is particularly challenging because flow velocity and gas composition can change dramatically within a very short period of time. Normal operation may involve extremely low flow, while plant shutdowns or emergency events can generate very high gas velocities.
Ultrasonic flare measurement provides the wide measuring range required to capture both conditions without introducing significant pressure loss or obstruction into the flare line.
Measurement of sound velocity and molecular weight also provides additional information about changing gas conditions, while integrated diagnostics continuously monitor instrument performance.
For plant operators, this provides reliable flare monitoring, improved loss detection, better process visibility and dependable measurement across changing operating conditions.
TSB Support in Jordan
TSB supplies Flare Ultrasonic Flow Meter solutions throughout Jordan and supports customers in selecting and configuring the appropriate system according to flare line size, gas composition, operating temperature, pressure and measurement requirements.
Our local support includes:
- Instrument and system selection
- Application engineering
- Flow meter configuration
- Flare application support
- Supply and commissioning
- Integration assistance
- Calibration and verification support
- After-sales service
- Spare parts support
- Preventive and corrective maintenance
- On-site technical support
- Troubleshooting assistance
Contact TSB for Flare Ultrasonic Flow Meter specifications, selection, pricing and configuration support in Jordan.