TDLAS / QF Analyzers

TSB supplies TDLAS and QF Gas Analyzers in Jordan for continuous, real-time measurement of critical gas components in natural gas, LNG, hydrogen, biomethane, CO₂, refinery and petrochemical applications.

Tunable Diode Laser Absorption Spectroscopy (TDLAS) provides highly selective optical measurement of gas components such as H₂O, H₂S and CO₂, while Quenched Fluorescence (QF) technology provides fast and stable oxygen measurement from trace ppm levels to percentage concentrations. These optical technologies are designed for high analyzer availability, rapid response and reduced maintenance requirements.

Product Overview

TDLAS / QF Analyzers combine:

  • Continuous online gas concentration measurement
  • Real-time process monitoring
  • TDLAS measurement of H₂O, H₂S, CO₂ and selected gas components
  • QF measurement of O₂ from trace to percentage levels
  • Low ppm measurement capability
  • Fast response to process changes
  • High selectivity for target gas components
  • Minimal contact between critical optical components and the process gas
  • Low maintenance requirements
  • Integrated diagnostics on selected configurations
  • Hazardous-area configurations
  • Complete sample conditioning system options

Typical Technical Capability

SpecificationTypical Capability
Measurement TechnologiesTDLAS / Quenched Fluorescence
TDLAS AnalytesH₂O, H₂S, CO₂ and selected components
QF AnalyteO₂
O₂ Measurement RangeFrom trace ppm levels up to 20 Vol.%
H₂S Measurement RangeFrom approximately 0–10 ppmv to 0–500 ppmv, with additional ranges available
Measured VariablesConcentration, cell pressure and cell temperature
MeasurementContinuous / online / real-time
Communication4–20 mA, Modbus RTU/RS485, Modbus TCP/Ethernet and selected digital outputs depending on analyzer
Hazardous AreasZone 1 / Zone 2 and Class I configurations depending on analyzer
ApplicationsNatural gas, LNG, hydrogen, biomethane, CO₂, refinery and petrochemical gases

Specifications and available options may vary. Contact TSB for full details and configuration support.

Key Features

  • Highly selective optical gas measurement
  • Fast response to changing gas concentrations
  • Reliable measurement at low ppm concentrations
  • Continuous real-time gas quality monitoring
  • TDLAS technology minimizes contact between critical analyzer components and the process stream
  • Reduced susceptibility to contamination compared with many conventional analyzer technologies
  • QF oxygen measurement is highly resistant to interference from H₂S, CO₂ and H₂O
  • No consumable chemicals required for QF measurement
  • High long-term measurement stability
  • Integrated analyzer diagnostics on selected configurations
  • Automatic validation and verification functions on selected TDLAS analyzers
  • Complete sample conditioning solutions available
  • Remote communication and system integration options
  • Hazardous-area configurations for oil, gas and petrochemical applications

Applications

  • Natural gas transmission
  • Natural gas processing
  • LNG plants
  • Biomethane and renewable natural gas
  • Hydrogen production and transport
  • CO₂ and CCUS applications
  • Gas quality monitoring
  • Moisture measurement
  • H₂S measurement
  • CO₂ measurement
  • Trace oxygen measurement
  • Refinery processes
  • Petrochemical plants
  • Gas storage
  • Gas distribution
  • Pipeline monitoring

Why Choose TDLAS / QF Analyzers?

TDLAS and QF technologies provide fast, selective and low-maintenance gas analysis for applications where continuous gas quality measurement is essential.

TDLAS uses a laser tuned to the absorption wavelength of the target gas component. This allows highly selective measurement of components such as moisture, hydrogen sulfide and carbon dioxide while reducing interference from other gases in the stream.

QF technology measures oxygen through fluorescence quenching and is particularly suitable for natural gas and other challenging gas streams. Unlike conventional galvanic oxygen cells, QF measurement is highly resistant to contamination from H₂S, CO₂ and moisture and does not require consumable chemicals.

For plant operators, this provides rapid process visibility, high analyzer availability, reduced maintenance and reliable measurement of critical gas quality parameters.

TSB Support in Jordan

TSB supplies TDLAS and QF Analyzer solutions throughout Jordan and supports customers in selecting the appropriate analyzer according to target component, gas composition, measuring range, pressure, hazardous-area requirements and process conditions.

Our local support includes:

  • Analyzer selection and technical consultation
  • Application engineering
  • Measurement range configuration
  • Sample conditioning system selection
  • Supply and commissioning
  • Analyzer integration
  • Calibration and validation support
  • After-sales service
  • Spare parts support
  • Preventive and corrective maintenance
  • On-site technical support
  • Troubleshooting assistance

Contact TSB for TDLAS / QF Analyzer specifications, selection, pricing and configuration support in Jordan.

endress.com

There are no reviews yet.

Be the first to review “TDLAS / QF Analyzers”

Technical Services Bureau Company, privately-owned company headquartered in Amman, Jordan. We began in 1977 and are recognized as a leader in technical services and engineering solutions in Jordan.

Contact Us

Call Us

+962 6 412 7967

Send A Message

tsb@tsb.com.jo

Our Location

Al Azraq Road, 200 Meters Before Grain Silos

Our Location

شركة المكتب الفني للخدمات، شركة خاصة يقع مقرها الرئيسي في عمان، الأردن. تأسست الشركة في عام 1977 وتُعَدّ من الرواد في مجال الخدمات التقنية والحلول الهندسية في الأردن.

تواصل معنا

اتصل بنا

7967 412 6 962+

ارسل رسالة

tsb@tsb.com.jo

موقعنا

طريق الأزرق، 200 متر قبل صوامع الحبوب

موقعنا

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.